Foundation Investigation in South Phoenix, AZ 12.2021
Challenge
This 1975 single-family home is on a conventional slab with the top of the footing at 15” below grade. Several symptoms prompted the current owner to have the foundation evaluated.
A Level A Foundation Inspection determined a Level B Foundation Investigation was needed.
Homeowner’s Concerns/Goals: The homeowner is primarily concerned with the exterior stair-stepping cracks.
Purpose of the Investigation: The purpose of this report is to evaluate the foundation and the foundation conditions of this property, and to perform a manometer and foundation survey on the interior of the property.
Scope of Services: The extent and scope of this manometer and foundation survey and assessment are detailed as follows:
• Perform a manometer survey.
• Locate the areas of foundation and floor slab failure, if any.
• Visually inspect and record the interior and the exterior of the location.
• Determine the extent of the foundation failure, if any.
• Prepare a documented repair plan if needed.
Limitations: The purpose of this report is limited to documenting and addressing the areas of concern indicated by the customer related to potential foundation movements. Arizona Foundation Solutions uses a variety of tools such as manometer survey, observations by technicians with notes and photographs, and industry standards such as the Foundation Performance Association (FPA) “Guidelines for the Evaluation of Foundation Movement for Residential and Other Low-Rise Buildings” to determine if foundation movement has impacted the serviceability of the home. The term serviceability relates to items such as pinched doors and windows, cracks in drywall and slabs, cracks in exterior stucco and walls, and the like. Recommendations in this report are made to address and limit future issues related to serviceability and the customer’s concern.
Unless expressly stated in the Safety and Structural Concerns section of this report, nothing in this report should be interpreted as a determination of structural inadequacy, an occupancy issue, or a safety issue.
This report offers no opinions as to the adequacy of the work of previous designers or contractors. This report is based on our observations and may not be indicative of all factors contributing to foundation and floor slab movement. Only a comprehensive geotechnical investigation and structural engineering investigation by licensed engineers would be able to determine all of the factors contributing to the failure of a foundation.
Foundation Footprint: A drawing of the footprint of the first floor was created and is included in this report.
Exterior Inspection: The exterior of the location was visually inspected. Items such as foundation cracks, exterior wall cracks, improper grading, type of structure, poor drainage, gutters or no gutters, bowed retaining walls, large trees close to the foundation, and any type of obstructions that may or may not influence the repair process were noted and recorded.
Interior Inspection: The interior of the location was visually inspected. Items such as floor cracks, wall cracks, ceiling cracks, sloping floors, uneven countertops, doors and windows that are out of alignment, cracked window glass, and bowed walls were noted and recorded.
Manometer Survey: The manometer survey, also known as a floor survey, is a measurement of the differences in interior floor elevations. The flatness of the interior floor was measured using a highly accurate survey device known as a Manometer. The entire interior floor area was surveyed and the elevations were recorded. These data points were then entered into a computer program that provides a topographical map showing the high and low elevation contours of the floor surface. This topographical map shows where the foundation is no longer level and shows where support and stabilization are needed. The floor survey also demonstrates whether any floor slab heave or settlement exists.
After examining the home and performing the manometer survey, Arizona Foundation Solutions believes the home could be experiencing minor foundation settlement at the perimeter walls/foundation at the east, southeast, and southwestern portions of the home and at the eastern and northwestern portions of the garage as shown by the damage (also known as Signs of Stress). Settlement can be caused by one or any combination of many factors including sub-grade saturation of moisture due to poor drainage, years of storm runoff, plumbing leaks, improper compaction, the lack of a proper foundation system, and/or (in most cases) natural earth movement.
While the southern portion of the home shows lower elevation readings, AZFS believes the AZ room is an addition and was poured at a slope due to the lack of damage in this area and the uniform nature of the sloping pattern. The AZ room should be monitored and should damage arise in the future, AZFS should be contacted to perform a comparative manometer survey at a discounted price.
Solution
The settlement at the perimeter walls/foundation at the east, southeast, and southwestern portions of the home and at the eastern and northwestern portions of the garage appears to be minor at this point in time. A protection plan has been designed to stop the area from any additional settlement and further damages. AZFS can permanently stabilize this area to protect the foundation from future settlement at the homeowner's discretion.
Arizona Foundation Solutions believes that the proper way to permanently stop the perimeter foundation settlement is to underpin the areas that are experiencing movement. Underpinning is the process of installing deep foundation elements called piles. Piles are engineered foundation supports that are driven down past the unstable soils and are then locked up into load-bearing strata, which can support the loads that are transferred to them. Once the piles have been installed, they can be used to lift the perimeter foundation up to its Highest Practical Maximum. The piles should be spaced approximately eight feet on center and should start and stop near the hinge points of movement (exact spacing to be determined after load-bearing calculations). In this case, the piles would be located at the east, southeast, and southwestern portions of the home and at the eastern and northwestern portions of the garage.
Since storm runoff is responsible for the majority of the moisture that pools next to the foundation, gutters need to be installed to prevent the storm runoff from increasing the amount of foundation movement. A proper gutter system should be installed to discharge the storm runoff a minimum of 10 feet, preferably 20 feet away from the foundation. We do not recommend installing gutters that discharge next to the foundation as this will only increase the probability of a foundation problem.
It is also beneficial to manage the moisture around your home using conventional means as outlined below:
-Hire a reputable plumbing leak detector and repair service to check both pressure and sewer lines, this is usually done for less than $500. If repairs are needed, they are usually not expensive.
-Make sure the grading of the terrain is sloped downwards at a 5% slope from the home at all areas of the perimeter.
-Stop irrigating plants that are near the foundation and make sure there is nothing -trapping the moisture from flowing away from the home.
-When permanently stabilizing, lifting, and/or mitigating a foundation movement problem, AZFS recommends waiting AT LEAST 6 months before investing in cosmetic repairs.
Safety or Structural Concerns: None