Gilbert, AZ Foundation Inspection & Repair 6.2021
Challenge
The owners of this late 1980’s single family, ranch style home reached out to us after noticing a few signs of a potential foundation problem.
These signs included:
- Exterior wall cracks
- Exterior cracks in the brickwork
- Interior wall cracks
- Gaps between the baseboard & floor
An initial, Level A (visual) Foundation Inspection indicated the need to have a Forensic Foundation Inspection or investigation (Level B Foundation Inspection).
Customers Goals:
1.) Fix the cracks in the garage
2.) Fix the horizontal stem wall cracks.
Exterior Inspection: The exterior of the location was visually inspected. Items such as foundation cracks, exterior wall cracks, improper grading, type of structure, poor drainage, gutters or no gutters, bowed retaining walls, large trees close to the foundation and any type of obstructions that may or may not influence the repair process were noted and recorded.
Interior Inspection: The interior of the location was visually inspected. Items such as floor cracks, wall cracks, ceiling cracks, sloping floors, uneven counter tops, doors and windows that are out of alignment, cracked window glass and bowed walls were noted and recorded.
Manometer Survey: The manometer survey, also known as a floor survey, is a measurement of the differences of interior floor elevations. The flatness of the interior floor was measured using a highly accurate survey device known as a Manometer. The entire interior floor area was surveyed and the elevations were recorded. These data points were then entered into a computer program that provides a topographical map showing the high and low elevation contours of the floor surface. This topographical map shows where the foundation is no longer level and shows where support and stabilization is needed. The floor survey also demonstrates whether any floor slab heave or settlement exists.
After examining the home and performing the manometer survey, Arizona Foundation Solutions believes the home could be experiencing minor foundation settlement at the western portion of the home and at the north, east and western portion of the garage as shown by the minor damage (also known as Signs of Stress) and lower readings on the Topographical Map. The drop off in floor elevations on the topographical map is consistent with a foundation settlement pattern. Foundation settlement can be caused by one or any combination of many factors including sub-grade saturation of moisture due to poor drainage, years of storm runoff, plumbing leaks, improper compaction, the lack of a proper foundation system, and/or (in most cases) natural earth movement.
A minor foundation heave pattern is observed in the northeast and northwestern portions of the home as indicated by the higher elevation readings on the 3D Topographical Map. This phenomenon usually occurs in areas where structures are built on expansive clays. Moisture from one or any combination of the following: storm runoff, poor drainage around the foundation, plumbing leaks and/or underground moisture sources will allow the moisture/vapor to accumulate underneath the foundation. The moisture then interacts with the clayey soils, causing them to swell. The clay soils take the path of least resistance and expand upwards and lift the foundation.
There is a crack in the floor slab. When the slab cracks all the way through, the separate sections can move independently of one another. This allows for severe damage to flooring and other signs of interior stress like pinched doors, drywall, and/or ceiling cracks.
The rebar in the concrete stem wall along certain sides of the home has begun to rust. This has caused the rebar to deteriorate and the iron oxide to expand. The expansion from the iron oxide generates enough pressure to crack the stem wall. The corrosion of the bar has to typically exceed 20% before there is enough pressure to crack the concrete stem wall. This issue should be dealt with properly to prevent the corrosion from spreading down the perimeter of the rebar and to return the original strength and span capacity to the stem wall.
The concrete stem wall in certain areas around the home appears to be spalling. Spalling is when the concrete face of the stem wall is deteriorating. Spalling can occur when there is excess moisture near the foundation, minerals in the soil, and/or when the concrete was not mixed correctly. This is most often a cosmetic issue but if deterioration has occurred underneath the loads of the structure, it is no longer considered cosmetic.
The Foundation Performance Association (FPA) “Guidelines for the Evaluation of Foundation Movement for Residential And Other Low-Rise Buildings” were adopted to correlate acceptable and unacceptable distress phenomena with actual survey elevations. Deflection and Tilt calculations were performed and compared to allowable values. For this engineered analysis, the deflection of the slab (L/908) was less than the allowable deflection limit of L/360. In addition, the tilt of the slab (0.08%) was less than the allowable tilt of 1.00%.
Solution
The foundation settlement at the western portion of the home and at the north, east and western portions of the garage appears to be minor at this point in time. A protection plan has been designed to stop the area from any additional settlement and further damages. AZFS can permanently stabilize this area to protect the foundation from future settlement at the Homeowners discretion.
Arizona Foundation Solutions believes that the proper way to permanently stop the perimeter foundation settlement is to underpin the areas that are experiencing movement. Underpinning is the process of installing deep foundation elements called piles. Piles are engineered foundation supports that are driven down past the unstable soils and are then locked up into load bearing strata, which can support the loads that are transferred to them. Once the piles have been installed, they can be used to lift the perimeter foundation up to it’s Highest Practical Maximum. The piles should be spaced approximately six to eight feet on center and should start and stop near the hinge points of movement (exact spacing to be determined after load bearing calculations). In this case, the piles would be located at the western portion of the home and at the eastern and western portions of the garage. The slab can then be treated by injecting a light weight expansive polyurethane to fill existing voids and lift the floor slab. This is done by drilling small 3/8” holes in the slab after which polyurethane grout is injected directly under the slab to raise it up to it’s Highest Practical Maximum. Using the expansive materials will help prevent additional slab settlement by compacting the upper layer of soil as it expands.
Arizona Foundation Solutions believes that the proper way to deal with foundation heave is by lowering and managing the moisture content of expansive clays that cause heaving. It is our recommendation to manage the moisture underneath the foundation through active soil depressurization. This process will remove existing moisture from the soil as well as new moisture from the expansive clays and will help bring the moisture content down to an optimal level using both convection and evaporation. This will mitigate future heaving of the clay soil and possibly allow existing heaving to subside. This process can take six months to several years to reach equilibrium. Minor movement may still occur, as the MoistureLevel® Smart Foundation System is intended to prevent significant and continual upward movement caused by moisture. Due to the heaves appearing to be minor at this point in time, the MoistureLevel® Smart Foundation System are being recommended as a preventative measure.
Composite interlocking (also known as Crack Stitching) can be performed to tie the broken pieces of the concrete together. The existing crack will be cleaned and non-parallel lines will be cut across the existing crack. Next carbon fiber laminate stitches will be inserted into the non-parallel cuts and then the gaps will be filled with a 2 part poly. Finally the crack should be ground smooth to minimize the differential. If done properly, this will allow the slab to function as one floating unit to help prevent the damages to flooring, ceiling and walls. If this is instead expansion joint separation, the joint should be cleaned, routed, and re-caulked with an expansive joint filler.
The spalling concrete stem wall can be cosmetically repaired. First, the face of the stem wall needs to be chipped back to fractured rock. Then a cementitious patch can be applied and finished smooth. Please wait at least one week before painting the surface.
Since storm runoff is responsible for the majority of the moisture that pools next to the foundation, gutters need to be installed and modified to prevent the storm runoff from increasing the amount of foundation movement. A proper gutter system should be installed to discharge the storm runoff a minimum of 10 feet, preferably 20 feet away from the foundation. We do not recommend installing gutters that discharge next to the foundation as this will only increase the probability of a foundation problem.
Project Summary
Engineer: NĂ©stor J. Brea